Eegeschaften
Voll Bore Design, ouni Drockverloscht.
Den integréierten Design vu Flow, Drock, Wireless Reading meets Monitoring Pipeline Requirement.
Breet Range.
Konfiguréiert Mat Remote Data Collector, Remote Connect To Smart Metering Plattform.
IP68 Schutzklass, fir laangfristeg Ënnerwaasseraarbecht ze garantéieren.
Low Consumption Design, Duebel D Gréisst Batterien kënne kontinuéierlech fir 15 Joer schaffen.
Bi-Directional Miessung Forward A Reverse Flow.
Datespeicherfunktioun kann 10 Joer Daten späicheren Dag, Mount a Joer abegraff.
9 Zifferen Multi-Linn LCD Display.Kann Kumulativ Flow, Instantane Flow, Flow, Drock, Temperatur, Fehleralarm, Flow Richtung etc.
Standard RS485 (Modbus) An OCT Pulse, Eng Vielfalt vun Optiounen, NB-IoT, GPRS,etc.
Edelstol 304 Päif, dat ass Spannmolding Patent, Elektrophorese mat Anti-Scaling.
No Sanitär Norm Fir Drénkwaasser.
Spezifikatioune
Max.Aarbechtsdrock | 1,6 MPa |
Temperatur Klass | T30, T50, T70, T90 (Standard T30) |
Genauegkeet Klass | ISO4064, Genauegkeet Klass 2 |
Kierper Material | STAINLESS Steel 304 (opt. SS316L) |
Batterie Liewen | 15 Joer (Verbrauch≤0,3mW) |
Schutz Klass | IP68 |
Ëmwelttemperatur | 40℃~+70℃, ≤100%RH |
Drock Verloscht | △P10 |
Klimatesch a mechanesch Ëmfeld | Klass O |
Elektromagnetesch Klass | E2 |
Kommunikatioun | RS485 (Baudrate ass justierbar); Puls, Opt.NB-IoT, GPRS |
Display | 9 Zifferen Multi-Linn LCD Display. Kann gläichzäiteg kumulative Flow, Momentan Flow, Flowrate, Drock, Temperatur, Fehleralarm, Flowrichtung etc. |
RS485 | Standardbaudrate 9600bps (opt.2400bps,4800bps), Modbus-RTU |
Verbindung | Flanges nach EN1092-1 (aner personaliséiert) |
Flow Profil Empfindlechkeet Klass | U5/D3 |
Donnéeën Stockage | Späichert d'Donnéeën, dorënner Dag, Mount a Joer fir 10 Joer. |
Frequenz | 1-4 Mol / Sekonn |
Miessunge Beräich (R500)
Nominell Gréisst | (mm) | 350 | 400 | 500 | 600 |
(Zoll) | 14 | 16 | 20 | 24 | |
Overload Flow Q4 (m3/h) | 2000 | 3125 | 5000 | 7875 | |
Permanent Flow Q3 (m3/h) | 1600 | 2500 | 4000 | 6300 | |
Transitional Flow Q2 (m3/h) | 5.12 | 8.00 | 12.80 | 20.16 | |
Minimum Flow Q1 (m3/h) | 3.20 | 5.00 | 8.00 | 12.60 | |
R = Q3/Q1 | 500 | ||||
Q2/Q1 | 1.6 |
Miessunge Beräich (R400)
Nominell Gréisst | (mm) | 350 | 400 | 500 | 600 |
(Zoll) | 14 | 16 | 20 | 24 | |
Overload Flow Q4 (m3/h) | 2000 | 3125 | 5000 | 7875 | |
Permanent Flow Q3 (m3/h) | 1600 | 2500 | 4000 | 6300 | |
Transitional Flow Q2 (m3/h) | 6,40 | 10.00 | 16.00 Auer | 25.20 | |
Minimum Flow Q1 (m3/h) | 4.00 | 6.25 | 10.00 | 15.75 | |
R = Q3/Q1 | 315 | ||||
Q2/Q1 | 1.6 |
Miessunge Beräich (R250)
Nominell Gréisst | (mm) | 350 | 400 | 500 | 600 |
(Zoll) | 14 | 16 | 20 | 24 | |
Overload Flow Q4 (m3/h) | 2000 | 3125 | 5000 | 7875 | |
Permanent Flow Q3 (m3/h) | 1600 | 2500 | 4000 | 6300 | |
Transitional Flow Q2 (m3/h) | 6,40 | 10.00 | 16.00 Auer | 25.20 | |
Minimum Flow Q1 (m3/h) | 4.00 | 6.25 | 10.00 | 15.75 | |
R = Q3/Q1 | 315 | ||||
Q2/Q1 | 1.6 |
Configuratioun Code
WM9100 | WM9100 Ultrasonic Waasser Meter |
Pipe Gréisst | |
350 DN350 | |
400 DN400 | |
... ... | |
600 DN600 | |
Typ | |
A4 Full Bore Four-Channel (U5/D3) | |
Stroumversuergung | |
1 Batterie | |
2 24VDC + Batterie | |
Kierper Material | |
S Edelstol 304 (Standard) | |
H Edelstol 316 | |
Drock | |
10.6Mpa | |
2 1.0Mpa | |
3 1.6Mpa | |
4 2,5Mpa | |
O Anerer | |
Verbindung | |
F Flange | |
Turn-down Verhältnis | |
1 R500 | |
2 R400 | |
3 R250 | |
Ausgang | |
R RS485 + OCT Puls (Standard) | |
O Anerer | |
Fakultativ Funktioun | |
N Keen | |
1 Drockmessung | |
2 Built-in Remote Reading Funktioun | |
3 Béid (1 an 2) |
Nominell Gréisst | (mm) | 350 | 400 | 500 | 600 |
(Zoll) | 14 | 16 | 20 | 24 | |
L-Längt (mm) | 500 | 600 | 600 | 800 | |
B-Breet (mm) | 505 | 565 | 670 | 780 | |
H-Hauteur (mm) | 593 | 648 | 743 | 853 | |
h - hauteur (mm) | 245 | 275 | 328 | 378 | |
D xn | 22 x16 | 26 x16 | 26 x20 | 30 x20 | |
K (mm) | 460 | 515 | 620 | 725 | |
Drock (MPa) | 1.0 | 1.0 | 1.0 | 1.0 | |
Gewiicht (kg) | 112 | 138 | 169 | 220 |
Bemierkungen: Aner Längt vum Päif kann personaliséiert ginn.